NDJ-1C-T
High-temperature Viscometer
A heated small-sample configuration for rotational viscosity testing at elevated temperatures, using a coaxial-cylinder measuring system.

Series illustration. Appearance and supplied configuration require confirmation. Screen imagery is illustrative.Dynamic viscosity
Measight DV2TLV is a heated small-sample rotational-viscometer configuration for viscosity measurements at elevated sample temperatures. The archived speed range is 0.1–200 rpm, with spindle Nos. 21, 27, 28 and 29 listed for the measuring system. Specify the actual test temperature, sample and cup/spindle combination so the heating package and usable viscosity range can be confirmed for the supplied revision.
Values apply to the stated configuration and test conditions.
| Display | 5-inch IPS touchscreen |
|---|---|
| Temperature control range | ambient–300 °C |
| Temperature accuracy | ±0.1 °C |
| Viscosity range | 2.5–1,000,000 mPa·s |
| Speed range | 0.1–200 rpm |
| Spindle system | No. 21, 27, 28 and 29 |
| Sample volume | 15–25 mL |
| Accuracy | ±1% full scale |
| Instrument dimensions | 300 × 300 × 540 mm |
| Net weight | 14.5 kg |
| Interface languages | Chinese and English |
| Repeatability | ±0.5% full scale |
Evaluate DV2TLV against the method for the heated sample, including loading, temperature equilibration and cleaning. A test on a hot-melt adhesive or wax needs confirmation of temperature capability and material compatibility; the product name alone is not proof that every heated sample or method is supported.
For a DV2TLV quotation, provide the sample, expected viscosity and unit, test temperature, required method, sample volume and reporting needs. State the destination power supply and quantity. Ask for an itemised spindle, container, temperature-equipment and software configuration, together with the available model-specific documents.
Request a configuration quoteThe archived measuring-system description lists 15–25 mL. Confirm the fill volume for the selected spindle and heated cup, including the loading and immersion procedure, before using that figure in a test plan.
Review sample conditioning, contact materials, temperature measurement and reading time first. Confirm any method-specific requirements and obtain the supplied operating and cleaning instructions before testing heated samples.
Contact our team for the current manual and configuration details.
Request documentation
High-temperature Viscometer
A heated small-sample configuration for rotational viscosity testing at elevated temperatures, using a coaxial-cylinder measuring system.

High-temperature Viscometer
A heated coaxial-cylinder configuration for small-sample testing. Match the spindle, speed and temperature to your measurement procedure.

High-temperature Viscometer
A heated small-sample model with a coaxial-cylinder chamber and low-speed settings for elevated-temperature viscosity measurements.