HADV-1
Touchscreen Rotational Viscometer
Touchscreen operation with 0.3–100 rpm speed selection and R2–R7 spindles. Includes a PT100 probe for temperature measurement.

Series illustration. Appearance and supplied configuration require confirmation. Screen imagery is illustrative.Rotational
Measight RVDV-1 is a RV-series rotational viscometer with a 5-inch touchscreen, a listed speed range of 0.3–100 rpm and standard R2–R7 spindles. It supports timed measurement and lists RS232 communication. Select the spindle and operating speed for the required test, and confirm the usable range and temperature accessories; a series-wide maximum does not define the range of every spindle.
Values apply to the stated configuration and test conditions.
| Display | 5-inch IPS touchscreen |
|---|---|
| Rotational speed | 0.3–100 rpm |
| Sample volume | 500 mL |
| Spindles | R2–R7 standard; R1 optional |
| Temperature probe | PT100, standard |
| Controller | ARM processor |
| Enclosure | All-metal enclosure |
| Computer interface | RS232 |
| Wireless connectivity | Bluetooth connection to a phone or computer |
| Timed measurement | Supported |
| Level indicator | Front-mounted level indicator |
| Viscosity range | 40–13,000,000 mPa·s |
| Accuracy | ±1% full scale |
| Speed control | Stepless within the model speed range |
| Temperature measurement range | 0–200 °C |
Selected specifications from the current catalog are shown below. Contact us for the complete model-specific datasheet, measurement range, accessories and supplied configuration.
Request the complete datasheetTimed measurements help keep the test duration consistent when comparing thixotropic samples. Level the instrument before testing and record the spindle, speed and sample temperature with each result. RS232 supports connection to compatible computer software or a micro-printer; confirm the software and accessory package with the quotation.
A thermostatic bath, low-viscosity adapter, viscosity reference fluids and micro-printer are available as optional accessories. Select the bath and sample container for the required test temperature.
For a RVDV-1 quotation, provide the sample, expected viscosity and unit, test temperature, required method, sample volume and reporting needs. State the destination power supply and quantity. Ask for an itemised spindle, container, temperature-equipment and software configuration, together with the available model-specific documents.
Request a configuration quoteR2–R7 are listed as standard, with R1 optional. Confirm the supplied set, matching sample container and immersion conditions. An optional spindle must be assessed as a specific configuration rather than added to every range claim.
A temperature probe measures temperature; it does not by itself heat or cool the sample. Confirm the probe supplied with the instrument and the separate bath, cup or conditioning equipment required by the test method.
Contact our team for the current manual and configuration details.
Request documentation
Touchscreen Rotational Viscometer
Touchscreen operation with 0.3–100 rpm speed selection and R2–R7 spindles. Includes a PT100 probe for temperature measurement.

Touchscreen Rotational Viscometer
A 5-inch touchscreen with 0.1–200 rpm speed selection and R2–R7 spindles for rotational testing. A PT100 temperature probe is included.