Kinematic and Engler Viscometry Equipment — series illustrationSeries illustration. Appearance and supplied configuration require confirmation. Screen imagery is illustrative.

Engler

SYA-266A

Engler Viscometer

Measight SYA-266A is an Engler viscometer using a relative efflux-time measurement. The reviewed catalog lists a 200 mL timed outflow volume, temperature control from room temperature +5 °C to 100 °C, and a water reference time of 51 ±1 seconds at 20 °C. Match the apparatus and conditioning procedure to the required Engler method; the outflow volume is not a substitute for the sample filling instructions.

  • Temperature control: Room temperature +5 °C to 100 °C
  • Temperature accuracy: ±0.2 °C
  • Sample outflow: 200 mL
Request a Quote

Technical specifications

Values apply to the stated configuration and test conditions.

Temperature controlRoom temperature +5 °C to 100 °C
Temperature accuracy±0.2 °C
Sample outflow200 mL
Heater power500 W
Standard water value51 ±1 seconds
Bath stirringElectric stirring
Measurement methodEngler relative efflux-time method
Reference water temperature20 °C

Choose your measurement configuration.

Selected specifications from the current catalog are shown below. Contact us for the complete model-specific datasheet, measurement range, accessories and supplied configuration.

Request the complete datasheet

Choosing the SYA-266A configuration

Choose SYA-266A when the required procedure reports an Engler result. A capillary kinematic-viscosity measurement or a rotational-viscosity result uses a different method. Before comparing those results, confirm the reporting requirement and any applicable method-specific relationship rather than applying an assumed universal conversion.

What to include in your SYA-266A enquiry

For a SYA-266A quotation, provide the sample, expected viscosity and unit, test temperature, required method, sample volume and reporting needs. State the destination power supply and quantity. Ask for an itemised spindle, container, temperature-equipment and software configuration, together with the available model-specific documents.

Request a configuration quote

Common questions

What does the SYA-266A water reference time mean?

The catalog lists 51 ±1 seconds for the water reference at 20 °C. It is a reference condition for the Engler apparatus, not the flow time of every test sample. Follow the supplied method for the reference and sample measurements.

Does the SYA-266A 200 mL figure specify the sample charge?

The reviewed value is the sample outflow volume. Confirm the filling mark, sample conditioning and collection procedure from the instrument instructions rather than treating the timed outflow volume as the initial charge.

Can SYA-266A directly replace a capillary kinematic viscometer?

Select according to the required measurement method and reporting unit. Engler relative efflux time and capillary kinematic viscosity are different procedures; establish any permitted correlation for the sample before substitution.

Which temperature conditions should be confirmed for SYA-266A?

The listed control range is room temperature +5 °C to 100 °C. Confirm the room conditions, target test temperature, bath medium and equilibration procedure; the lower limit is relative to ambient temperature.

Documentation

Contact our team for the current manual and configuration details.

Request documentation

Related instruments

Kinematic and Engler Viscometry Equipment — series illustration

SYA-265C

Kinematic Viscometer

A four-position capillary system for kinematic viscosity measurements in mm²/s, with temperature control from room temperature to 100 °C.

View details
Kinematic and Engler Viscometry Equipment — series illustration

SYD-265B

Kinematic Viscometer

A two-position capillary system for kinematic viscosity measurements, with eight supplied capillaries and sample temperature control.

View details