SYA-265C
Kinematic Viscometer
A four-position capillary system for kinematic viscosity measurements in mm²/s, with temperature control from room temperature to 100 °C.

Series illustration. Appearance and supplied configuration require confirmation. Screen imagery is illustrative.Engler
Measight SYA-266A is an Engler viscometer using a relative efflux-time measurement. The reviewed catalog lists a 200 mL timed outflow volume, temperature control from room temperature +5 °C to 100 °C, and a water reference time of 51 ±1 seconds at 20 °C. Match the apparatus and conditioning procedure to the required Engler method; the outflow volume is not a substitute for the sample filling instructions.
Values apply to the stated configuration and test conditions.
| Temperature control | Room temperature +5 °C to 100 °C |
|---|---|
| Temperature accuracy | ±0.2 °C |
| Sample outflow | 200 mL |
| Heater power | 500 W |
| Standard water value | 51 ±1 seconds |
| Bath stirring | Electric stirring |
| Measurement method | Engler relative efflux-time method |
| Reference water temperature | 20 °C |
Selected specifications from the current catalog are shown below. Contact us for the complete model-specific datasheet, measurement range, accessories and supplied configuration.
Request the complete datasheetChoose SYA-266A when the required procedure reports an Engler result. A capillary kinematic-viscosity measurement or a rotational-viscosity result uses a different method. Before comparing those results, confirm the reporting requirement and any applicable method-specific relationship rather than applying an assumed universal conversion.
For a SYA-266A quotation, provide the sample, expected viscosity and unit, test temperature, required method, sample volume and reporting needs. State the destination power supply and quantity. Ask for an itemised spindle, container, temperature-equipment and software configuration, together with the available model-specific documents.
Request a configuration quoteThe catalog lists 51 ±1 seconds for the water reference at 20 °C. It is a reference condition for the Engler apparatus, not the flow time of every test sample. Follow the supplied method for the reference and sample measurements.
The reviewed value is the sample outflow volume. Confirm the filling mark, sample conditioning and collection procedure from the instrument instructions rather than treating the timed outflow volume as the initial charge.
Select according to the required measurement method and reporting unit. Engler relative efflux time and capillary kinematic viscosity are different procedures; establish any permitted correlation for the sample before substitution.
The listed control range is room temperature +5 °C to 100 °C. Confirm the room conditions, target test temperature, bath medium and equilibration procedure; the lower limit is relative to ambient temperature.
Contact our team for the current manual and configuration details.
Request documentation
Kinematic Viscometer
A four-position capillary system for kinematic viscosity measurements in mm²/s, with temperature control from room temperature to 100 °C.

Kinematic Viscometer
A two-position capillary system for kinematic viscosity measurements, with eight supplied capillaries and sample temperature control.