DV79 Touchscreen Viscometer Series — series illustrationSeries illustration. Appearance and supplied configuration require confirmation. Screen imagery is illustrative.

Rotational

DV79A

Rotational Viscometer

Measight DV79A measures dynamic viscosity with a Type A container and a 70 mL sample configuration. The listed range is 1–50 mPa·s across matching spindle/speed combinations, with selectable speeds of 7.5, 75 and 750 rpm. The catalog also lists temperature measurement and RS232 output. Choose the matching cup and spindle; the overall range is not available from every combination.

  • Rotational speeds: 7.5, 75, 750 rpm
  • Sample volume: 70 mL
  • Communication: RS232
Request a Quote

Technical specifications

Values apply to the stated configuration and test conditions.

Rotational speeds7.5, 75, 750 rpm
Sample volume70 mL
CommunicationRS232
Torque operating range10–100%
Viscosity range1–50 mPa·sWith the Type A container and its matching spindles. Each spindle/speed combination covers part of this range.
Spindle systemA, B, C and D spindles with Type A container
Accuracy±1% full scale
Repeatability±0.5% full scale
Input power110–220 V, 50 ±1 Hz
Temperature probeRTD probe
Drive systemStepper motor with microprocessor control
Displayed valuesViscosity, speed, temperature, torque percentage and spindle number
Catalog temperature accuracy0.1 °C
Temperature measurement range0–200 °C

Choose your measurement configuration.

Selected specifications from the current catalog are shown below. Contact us for the complete model-specific datasheet, measurement range, accessories and supplied configuration.

Request the complete datasheet

Use the correct spindle and torque range

Use the spindle specified for the selected container. The catalog identifies readings below 10% or above 100% torque as invalid. Record temperature and speed alongside the viscosity result.

Type A measurement configurations

At 750 rpm: spindle A covers 1–10 mPa·s (3,550 s⁻¹); B covers 2–20 mPa·s (1,855 s⁻¹); C covers 4–40 mPa·s (1,006 s⁻¹); D covers 5–50 mPa·s (836 s⁻¹). These shear rates apply to the listed spindle/container geometries and the 70 mL sample configuration.

Choosing the DV79A configuration

Consider DV79A when the sample and method fit the Type A low-viscosity configuration. For example, the catalog lists 1–10 mPa·s for spindle A at 750 rpm with the matching 70 mL Type A setup. A different spindle or speed needs its own working-range check.

What to include in your DV79A enquiry

For a DV79A quotation, provide the sample, expected viscosity and unit, test temperature, required method, sample volume and reporting needs. State the destination power supply and quantity. Ask for an itemised spindle, container, temperature-equipment and software configuration, together with the available model-specific documents.

Request a configuration quote

Common questions

Can DV79A temperature measurement replace a temperature-control setup?

The RTD probe measures sample temperature. It does not by itself establish heating or cooling capability. Specify the required test temperature and confirm how the selected cup will be conditioned and held at that temperature.

Documentation

Contact our team for the current manual and configuration details.

Request documentation

Related instruments

DV79 Touchscreen Viscometer Series — series illustration

DV79B

Rotational Viscometer

Three selectable speeds and a 15 mL sample configuration for rotational viscosity measurements when sample quantity is limited.

View details
4.3-inch Pro Touchscreen Viscometer Series — series illustration

LV-SSA

Small-sample Touchscreen Viscometer

A coaxial-cylinder measuring system for small sample quantities, with touchscreen operation and adjustable rotational speed.

View details